Electricity
2.1. Electric current
Introduction: The rate of flow of charge is called electric current. In the case of metallic conductors, free electrons are the carriers of charge. To make electrons, which move randomly, move in a specific direction, an electromotive force (EMF) is applied. For this, a source of electric potential is connected across the two ends of the conductor. Electric cells, batteries, battery eliminators, etc., are such sources.
2.1.1. Electric cell
In the laboratory, chemical cells are generally used as the source of electric current. Cells are of two categories: primary cells and secondary cells.
(a) Primary cell: Electricity is generated in this cell with the help of chemical reactions. This cell cannot be reactivated by supplying energy from outside. Leclanche, Daniell, etc., are cells of this category.
- Leclanche cell: Invented by Georges Leclanche (1839-82), this cell consists of an amalgamated zinc rod as the negative electrode and a carbon rod as the positive electrode. The zinc rod is immersed in an exciting liquid $NH_4Cl$ solution in a glass vessel. A carbon rod is buried inside a porous porcelain pot containing $MnO_2$. Carbon powder is added to the $MnO_2$ to increase conductivity. Its electromotive force is $1.4$ volts.
- Daniell cell: Here, an amalgamated zinc plate is immersed in dilute sulfuric acid ($H_2SO_4$) in a porous porcelain pot. The pot is kept immersed in a concentrated copper sulfate ($CuSO_4$) solution in a copper vessel. To maintain the concentration of the solution, $CuSO_4$ crystals are kept in a perforated shelf. The copper vessel acts as the positive electrode and the zinc plate as the negative electrode. Its electromotive force is $1.08$ volts.
- Dry cell: This is a modified Leclanche cell. It consists of a zinc cylinder, which is the negative pole of the cell. The positive pole is a carbon rod. It is placed in the center of the cylinder inside a mixture of $NH_4Cl$, $MnO_2$, and carbon powder. Inside the cylinder, there is a muslin cloth lining. Tarred paper is placed under the carbon rod to insulate it from the cylinder. On top, there are three layers of pitch, sand, and sawdust. Its electromotive force is $1.5$ volts.
(b) Secondary cell: In this cell, electrical energy is converted into chemical energy and stored. It can be reactivated by supplying electrical energy from outside. Lead-acid accumulator cells, Ni-Fe cells, etc., are cells of this class.
Standard cell: Cells that have a specific electromotive force at a specific temperature are called standard cells. The electromotive force of other voltaic cells is not always the same. However, at a specific temperature, the EMF of a standard cell is fixed. Standard cells are used as reference cells to determine the EMF of other cells, and for calibrating ammeters, voltmeters, etc. The Weston cadmium cell belongs to this category.
Battery: A combination of two or more cells is called a battery. Cells can be connected in series, in parallel, or in a mixed arrangement.
Battery eliminator: It is used to convert A.C. to D.C. It is used instead of a cell. With its help, 220 volts A.C. can be converted to low-value D.C. voltages like 2V, 4V, 6V, etc.
2.1.2. Commonly used electrical equipment
To perform electrical experiments, one should know in detail about the following tools:
(a) Keys:
- Plug key: Used to open or close an electrical circuit. One-way, two-way, or four-way keys are used as required.
- Two-way key: Used to connect two different circuits one by one. It has a common connection key.
- Four-way key: Can connect four different segments to a common point. Generally used in potentiometers.
- Tapping key: Used when electric current is required in a circuit for a short moment.
(b) Plug commutator: Used to change the direction of current in the circuit.
(c) Resistance:
- Resistance coil: A specific resistance wire is folded in two and its two ends are soldered to two metal posts.
- Resistance box: Coils of resistance wire are connected in series inside a box. Inserting a plug removes the resistance; removing the plug includes it in the circuit.
- Rheostat: A continuously variable resistance. It has nichrome wire wound on a porcelain cylinder with a sliding jockey to change resistance.
- Colour code of carbon resistors: The value of carbon resistors used in electrical or transistor circuits is expressed by color bands. The first two bands indicate the first two digits, the third is the multiplier (power of ten), and the fourth is the tolerance.
Color Digit Multiplier Color Tolerance Black 0 $10^0$ Silver 10% Brown 1 $10^1$ Gold 5% Red 2 $10^2$ No color 20% Orange 3 $10^3$ Yellow 4 $10^4$ Green 5 $10^5$ Blue 6 $10^6$ Violet 7 $10^7$ Grey 8 $10^8$ White 9 $10^9$
(d) Galvanometer: Used to detect the presence of current in a circuit. Usually, a moving coil or pointer galvanometer is used.
(e) Ammeter: Used to measure direct current. It is a pointer galvanometer with a low resistance connected in parallel. Connected in series in a circuit.
(f) Voltmeter: Used to measure the potential difference between two points. It is a pointer galvanometer with a high resistance connected in series. Connected in parallel in a circuit.
2.1.3. Precautions for electrical experiments:
- Draw the circuit diagram clearly in the notebook before starting. Clean the ends of connecting wires with sandpaper. Connections should be tight so they don't come off when pulled.
- Keep the key open while making connections.
- When inserting plugs in a resistance box, press and twist slightly so they fit tightly.
- When connecting a sensitive galvanometer, use a low resistance in parallel or a high resistance in series.
- Connect the positive pole of ammeters and voltmeters to the high potential point and the negative to the low potential point.
- When using a storage cell in meter bridge or PO box experiments, connect a suitable resistance ($\approx 100 \Omega$) in series.
- Close the plug key only while taking observations. Otherwise, wires will heat up.
- When changing the direction of current using a plug commutator, open both keys together.
- To find the deflection of a galvanometer, first close the battery circuit and then the galvanometer circuit.
- Before connecting, check the EMF of the cell. Do not use a lead accumulator if its EMF is less than 1.9V, or an alkali accumulator if less than 1.1V.
- After the experiment, disconnect all connections and keep the equipment in their respective places.
2.2. Measurement of resistance
Ohm's Law: At a constant temperature, the current ($I$) flowing through a conductor is proportional to the potential difference ($V$) across its ends. So, $V \propto I$ or $\frac{V}{I} = R$ (constant). The constant $R$ is called the resistance of the conductor. Unit is Ohm ($\Omega$).
Resistivity: The resistance ($R$) of a conductor is directly proportional to its length ($l$) and inversely proportional to its cross-sectional area ($A$). $R \propto l/A \Rightarrow R = \rho l/A$. The constant $\rho$ is the resistivity. Its unit is Ohm-meter ($\Omega \cdot m$).
Experiment A-1
Objective: To observe the variation of potential difference ($V$) across a given resistance by changing current ($I$) through it. Draw I-V graph and find the value of given resistance from it.
Apparatus: Given resistance, voltmeter, ammeter, battery, rheostat, key, connecting wires, etc.
Principle: By Ohm's law, $V = RI$. Therefore, the V vs I graph will be a straight line. The slope ($V/I$) gives the resistance.
Observation Table:
| Sl No. | Ammeter Reading (I) (Ampere) |
Voltmeter Reading | ||
|---|---|---|---|---|
| Increasing I (Volts) | Decreasing I (Volts) | Mean V (Volts) | ||
| 1 | ||||
| 2 | ||||
| 3 | ||||
| 4 | ||||
Result: The V-I graph is a straight line, verifying Ohm's law. The resistance $R = V/I = \dots \Omega$.
Viva-Voce Questions
Q: What is Ohm's law?
A: At a constant temperature, the current flowing through a conductor is directly proportional to the potential difference across its ends.
Q: Does resistance depend on temperature?
A: Yes. Resistance increases as temperature increases.
Q: What is the function of the rheostat here?
A: It is used to vary the current in the circuit to take multiple readings.
Q: Why must ammeter resistance be low?
A: So that inserting it in the circuit does not significantly alter the main current.
Experiment A-2
Objective: To construct a potential divider with the help of a rheostat and a battery and use it to verify Ohm's law.
Apparatus: Battery, rheostat, ammeter, voltmeter, key, resistance, connecting wires.
Principle: Same as A-1. $V = RI$. Connecting the two fixed terminals of a rheostat to a battery allows it to act as a potential divider.
Observation Table:
| Sl No. | Ammeter Reading I (A) | Voltmeter Reading V (Volts) | ||
|---|---|---|---|---|
| Apparent I | Corrected I | Apparent V | Corrected V | |
| 1 | ||||
| 2 | ||||
Result: The V-I graph is a straight line passing through the origin, verifying Ohm's law.
Viva-Voce Questions
Q: What is a rheostat? How is it used?
A: It is a continuously variable resistor. It is used to change the current in a circuit. Also, it can be used to control potential using the potential divider method.
Q: What is the potential divider method?
A: The method of applying different potentials in an external circuit even when the main potential is constant is called the potential divider method.
2.3. Principle of Wheatstone's bridge
Four resistances $P, Q, R, S$ are arranged in a quadrilateral. A cell is connected across one diagonal and a galvanometer across the other. When adjusted such that no current flows through the galvanometer, the bridge is balanced. At balance: $\frac{P}{Q} = \frac{R}{S}$.
Meter bridge: Uses a 1-meter uniform wire. If balance point is at length $l$ from the left, then $\frac{P}{Q} = \frac{l}{100-l}$. Therefore, unknown resistance $X = \frac{100-l}{l}R$.
Experiment A-3
Objective: To find the resistance using a metre bridge.
Apparatus: Metre bridge, Leclanche cell, galvanometer, resistance box, key, unknown resistance wire, etc.
Observation Table:
| Observation | Resistance Box R ($\Omega$) | Balance length l (cm) | Length (100-l) (cm) | Unknown Resistance $X = (\frac{100-l}{l})R$ ($\Omega$) |
|---|---|---|---|---|
| 1 | R | |||
| 2 | R+1 | |||
| 3 | R+2 |
Result: The average unknown resistance $X = \dots \Omega$.
Viva-Voce Questions
Q: Why is the instrument you are using called a meter bridge?
A: Its working principle is based on Wheatstone's bridge principle. Also, the length of the wire is 1 meter. Hence, it is called a meter bridge.
Q: Can it be used to measure very low or very high resistances?
A: In this case, the sensitivity of the instrument decreases. So, an accurate value cannot be obtained.
Q: Why do you need to find the balance point in the middle of the wire?
A: If the balance point is in the middle of the wire, the accuracy is highest.
2.4. Measurement of electromotive force and potential difference
Electromotive force (EMF): Potential difference between the poles of a cell in an open circuit.
Terminal potential difference: Potential difference across the poles when current is flowing (closed circuit).
Internal resistance ($r$): The resistance offered by the electrolyte inside the cell. $E = I(R+r)$ and $V = IR \implies r = R(\frac{E-V}{V})$.
2.4.1. Potentiometer: Used to measure EMF and potential drop accurately. Principle: The potential drop across any length of a uniform wire carrying steady current is proportional to its length ($V \propto l \implies V = Kl$). $K$ is the potential gradient.
Experiment A-4
Objective: To compare the emf of two primary cells using a potentiometer.
Apparatus: Potentiometer, battery, two test cells (Leclanche and Daniell), ammeter, voltmeter, galvanometer, rheostat, resistance box, two-way key, key, etc.
Principle: If $l_1$ and $l_2$ are balancing lengths for cells $E_1$ and $E_2$, then $E_1 = Kl_1$ and $E_2 = Kl_2$. Therefore, $\frac{E_1}{E_2} = \frac{l_1}{l_2}$.
Result: The ratio of EMFs of the two cells is = $\dots$
Precautions: EMF of driver cell must be strictly greater than the EMFs of cells to be compared. Current must remain constant.
Experiment A-5
Objective: To determine the internal resistance of a given cell using a potentiometer.
Principle: Let $l_1$ be balance length for open circuit cell ($E = Kl_1$) and $l_2$ be balance length when cell is shunted with resistance $R$ ($V = Kl_2$).
Internal resistance $r = (\frac{l_1 - l_2}{l_2})R$.
Observation Table:
| Observation | Shunt Resistance R ($\Omega$) | Balance point for open cell $l_1$ (cm) | Balance point for closed cell $l_2$ (cm) | Internal Resistance $r = (\frac{l_1 - l_2}{l_2})R$ ($\Omega$) |
|---|---|---|---|---|
| 1 | 3 | |||
| 2 | 4 | |||
| 3 | 5 |
Viva-Voce Questions
Q: Why use a potentiometer instead of a voltmeter to measure EMF?
A: At the null point, no current is drawn from the cell. Hence, internal resistance causes no voltage drop, giving the true EMF. Voltmeter draws some current.
Q: What is the most critical condition to observe in this experiment?
A: The EMF of the driver battery must be greater than the EMF of the test cell. Otherwise, the potential difference across the potentiometer wire will be less than the cell's EMF, and a balance point will not be found.
Q: On what factors does internal resistance depend?
A: (1) Directly proportional to the distance between electrodes. (2) Inversely proportional to the area of electrodes immersed. (3) Inversely proportional to the specific conductivity of the electrolyte. (4) Internal resistance decreases if the current drawn from the cell increases.
2.5. Galvanometer, ammeter and voltmeter
Galvanometer: Used to measure current flowing through a circuit. Usually, a moving coil galvanometer is used in the laboratory.
Galvanometer to Ammeter: A low resistance called a shunt ($S$) is connected in parallel. $S = \frac{I_g}{I - I_g} G$.
Galvanometer to Voltmeter: A high resistance ($R$) is connected in series. $R = \frac{V}{I_g} - G$.
Experiment A-6(a)
Objective: To convert a galvanometer of known resistance into an ammeter of desired range and to verify the same.
Procedure: Calculate required shunt $S = \frac{I_g}{I - I_g} G$. Use a copper wire of appropriate length $l = \frac{\pi r^2}{\rho}S$ to act as the shunt. Connect in parallel. Verify readings against a standard ammeter connected in series.
Verification Table:
| Observation | Deflection ($\theta$) | Current $I_1 = \theta \times \text{L.C.}$ (A) | Standard Ammeter Reading $I_2$ (A) | Difference $I_2 \sim I_1$ (A) |
|---|---|---|---|---|
| 1 | ||||
| 2 | ||||
| 3 |
Result: It is seen that the difference between the true current and experimental current ($I_2 - I_1$) is very small. Therefore, the conversion is correct.
Experiment A-6(b)
Objective: To convert a given galvanometer into a voltmeter of given range and verify the same.
Procedure: Calculate required series resistance $R = \frac{V}{I_g} - G$. Apply this resistance from a high-resistance box in series with the galvanometer. Verify against a standard voltmeter connected in parallel.
Verification Table:
| Observation | Deflection ($\theta$) | Potential Diff $V_1 = \theta \times \text{L.C.}$ (V) | Standard Voltmeter Reading $V_2$ (V) | Difference $V_2 \sim V_1$ (V) |
|---|---|---|---|---|
| 1 | ||||
| 2 | ||||
| 3 |
Result: It is seen that the difference between the true PD $V_2$ and calculated PD $V_1$ is very small. Therefore, the conversion is correct.
Viva-Voce Questions
Q: What is a galvanometer?
A: An instrument used to measure the current flowing through a circuit is called a galvanometer.
Q: Why are marks made on both sides of zero on the galvanometer scale?
A: Because it is used to observe null deflection, marks are made on both sides of zero on the galvanometer scale to show deflection in either direction.
Q: Does a galvanometer have positive and negative poles?
A: No. A galvanometer does not have positive or negative poles.
Q: What is the figure of merit of a galvanometer?
A: The amount of current passed through a galvanometer that produces a deflection of one division on its scale is called its figure of merit.
Q: What is current sensitivity?
A: The deflection produced by passing a unit current through the galvanometer is called its current sensitivity.
Q: What is the relationship between current sensitivity and figure of merit?
A: Current sensitivity is the reciprocal of the figure of merit. The lower the sensitivity, the higher the figure of merit.
Q: What is the difference between a galvanometer and an ammeter?
A: Compared to a galvanometer, an ammeter has a low resistance. A galvanometer is converted into an ammeter by connecting a shunt in parallel with it.
Q: Why must a voltmeter have a high resistance?
A: A voltmeter is connected in parallel between two points in a circuit. Therefore, if its resistance is low, most of the circuit's current will flow through it. As a result, the potential difference to be measured will decrease.
Q: What is meant by the range of a voltmeter?
A: The maximum potential difference that the voltmeter can measure is called its range.